    Selection of generator sets and precautions when using water pumps and power
    Haixing Generator often receives consultation information from customers on the selection of generator sets. Below, Haixing will give you some suggestions on the selection of generator sets, hoping to help you. In addition, the following also describes the precautions when using generators, water pumps, and power that many customers are concerned about. 1. Because the actual output power of generators, water pumps, and power will be affected by factors such as altitude, temperature, and environmental humidity. When the altitude, temperature, and ambient humidity increase, the power of the generator will decrease in different proportions. Please refer to the relevant information of the generator. Please take it into consideration when calculating the power of the generator, and then purchase to avoid it. Insufficient power is used. 2. For electrical appliances with the same power, due to different types of electrical appliances, the starting current is very different, and the demand for generator power is different. Therefore, when users purchase products, they should first calculate how many high-power generators can meet normal use. Tool
  • Feb
    28
    Routine maintenance of generators can extend service life
    The generator set requires maintenance for long-term use or after being used for a long time. In order to maintain the performance of the generator set and keep the generator in good condition. The following is a case where a customer's generator failed due to long-term use. Some problems that arise during regular maintenance, as well as the maintenance process. There are mainly these steps for generator maintenance. The first and most important maintenance is to add engine oil through the oil filler port before starting the generator. When filling, the engine should be placed in a horizontal position and pay attention to changes in the generator oil level. Generators require the use of multi-grade viscosity engine oil, because multi-grade viscosity engine oil is suitable for a wider operating temperature range and the consumption rate is about 30% lower than single-grade viscosity engine oil. After adding oil, wait for a while before looking at the oil level on the generator oil dipstick. The correct value is the oil level you see after all the oil has flowed into the oil pan. Each oil filter should be filled with clean oil before it can be installed on the engine. Engine oil performance grade representative
  • Feb
    28
    Haixing points out common misoperations of diesel generators
    Improper operation of diesel generators will seriously affect the service life of diesel generators. Now Haixing will work with everyone to understand what are the incorrect operation methods of diesel generators in daily life? Haixing believes that correcting the problems during the use of diesel generators in a timely manner Wrong operation can avoid accidents to a large extent, facilitate maintenance work, and extend the service life of the equipment. There are many benefits! 1: When the diesel engine is running when there is insufficient engine oil, insufficient oil supply will cause insufficient oil supply on the surfaces of each friction pair, resulting in abnormal wear or burns. For this reason, it is necessary to ensure sufficient engine oil before starting the diesel generator and during the operation of the diesel engine to prevent cylinder pulling and tile burning failures due to lack of oil. 2: Stop the diesel engine immediately after the load is suddenly stopped or the load is suddenly removed. After the generator stalls, the circulation of the cooling system water stops, the heat dissipation capacity is sharply reduced, and the heated parts lose cooling, which can easily cause the cylinder head, cylinder liner, cylinder block and other mechanical parts.
  • Feb
    28
    Solve common problems of small and medium-sized generators [Haixing Technology]
    Solve common problems of small and medium-sized generators 1. If not used for a long time (more than three months), follow the following steps to store it A. Drain all the gasoline in the fuel tank and carburetor B. Drain all the oil in the crankcase C. Add new engine oil to the upper limit of the oil level on the oil dipstick D. Close the choke and pull the starter handle to where resistance is felt E. Wipe the unit clean and cover it with a carton or plastic cover to prevent dust————————————————————————2. Why does the machine stop automatically when there is insufficient oil? When the engine oil is insufficient, the oil warning switch inside the engine will ground the primary coil of the ignition coil, causing the ignition coil to fail to ignite and the engine to stall. How to check whether the oil level is standard: Place the engine in a horizontal position, unscrew the oil dipstick, clean and dry it, then insert it into the oil inlet (no need to rotate), then pull it out, and check that the oil level is above the middle of the dipstick. ---------------
  • Feb
    28
    How to use diesel generator sets correctly and safely in enterprises and companies [Haixing Technology]
    How to use diesel generator sets correctly and safely in enterprises and companies is a question that many customers have. Here, Haixing Generator Group gives you some suggestions: 1. Diesel generator sets must be staffed by personnel who are familiar with the unit structure and master the safe operating procedures. operate. New or newly overhauled diesel units must undergo 60 hours of running-in operation and be well maintained as required. 2. New or long-term unused generators must undergo strict inspection before being put into normal operation, mainly checking the winding insulation condition, wiring condition, etc. If there are any discrepancies, they will be dealt with. 3. After the diesel engine is started, the speed should be slowly increased. After checking and confirming that everything is in good condition, the diesel engine can be operated without load from low speed to rated speed. When running without load, focus on checking the engine oil pressure, whether there are any abnormal noises, changes in excitation current, three-phase voltage, etc. If there are any abnormalities in 4. Stop the machine immediately for inspection. After finding out the situation, start again. If everything is normal, that is
  • Feb
    28
    Expose the true face of 'abnormal noise' in the cylinder
    Analyze 'abnormal noises' in diesel engines and engine cylinders, which can be summarized as piston knocking sounds, piston pin knocking sounds, piston top hitting the cylinder head, piston top hitting sounds, piston ring knocking sounds, and valve knocking sounds. and cylinder knocking sounds, etc. Then Haixing Generator Company will analyze the true nature of these 'abnormal noises' for everyone. 1. The impact sound of the piston top and the cylinder head. The abnormal sound of the piston top hitting the cylinder head is a continuous metal knocking sound, which is especially obvious at high speeds. The source of the abnormal sound is in the upper part of the cylinder, the sound is solid and powerful, and the cylinder head vibrates. The main reasons are as follows. (1) The crankshaft bearing, connecting rod bearing and piston pin hole are severely worn, and the matching clearance seriously exceeds the standard. At the moment when the piston stroke changes, the top of the piston hits the cylinder head under the action of inertial force. (2) Due to the mistaken installation of other pistons of similar specifications when replacing the piston, or fake products, the distance from the center line of the piston pin hole to the top surface of the piston is greater than the original piston, causing the piston to become damaged.
  • Feb
    28
    Analysis of the 'cylinder pulling' or 'cylinder biting' of the generator set
    Many users do not know much about the reasons for 'cylinder pulling' or 'cylinder biting' of diesel generator sets. Today, technicians from Haixing Generator Set Manufacturer are here to popularize the technical knowledge of cylinder pulling of diesel generator sets to Guangfa users: 1. What is 'pull cylinder'? 'Pull the cylinder' is also called 'biting the cylinder'. It is stripe-like, colored damage that appears on the surface of the cylinder and piston rings along the direction of piston movement. Many customers of Haixing are very troubled by the phenomenon of cylinder pulling in diesel generator sets. When cylinder pulling occurs, the wear of the cylinder liner is very severe, which can reach dozens or even hundreds of times of normal wear. After a cylinder pull occurs, the external characteristics of the diesel engine pull steel are that the sound changes and black smoke is emitted from the exhaust. The consequences are that the working surfaces of the piston, piston ring and cylinder liner are damaged, the gas seal fails, the consumption of engine oil and the amount of blow-by gas increase rapidly, making the engine unable to operate normally, and even in a short period of time, due to the failure of the piston, piston ring and cylinder The set bites to death and stops
  • Nov
    29
    Maidao Wastewater Treatment Plant’s biogas power generation generates more than 9 million kWh/year with considerable environmental benefits
    According to news reports, Qingdao currently has 23 sewage treatment plants in operation, with a total treatment capacity of 1.7 million cubic meters per day. The annual biogas power generation capacity of Maidao Sewage Treatment Plant is more than 9 million kilowatt-hours. Based on the average annual electricity consumption of 1,200 kilowatt-hours per household in Qingdao, it is equivalent to the annual electricity consumption of 7,000 households. According to reports, Qingdao's sewage treatment plant leads the country in sludge digestion and stabilization, biogas power generation, and waste heat recovery and utilization. The China Urban Water Supply and Drainage Association plans to hold an on-site meeting in 2016 to promote Qingdao's experience. The reasonable disposal and comprehensive utilization of sludge, biogas and waste heat have significant economic, social and environmental benefits. Taking Maidao Sewage Treatment Plant as an example, the sludge generated during the sewage treatment process is reduced, stabilized and harmlessly treated through the anaerobic digestion process, achieving a sludge reduction of nearly 40%, which greatly saves sludge transportation and follow-up. disposal costs; anaerobic digestion produces about 6 million cubic feet of biogas annually.
  • Nov
    29
    How to evaluate the quotation of second-hand generator sets
    After summarizing years of unit experience, generator manufacturers have also summarized some reliable methods for estimating the price of second-hand diesel generator sets. The following diesel generator manufacturers will share this method with everyone. The method can be based on the method of first asking, second looking, and third testing, with testing as the main method. First question: It is to ask about the purchase time, purpose and reason of sale of the diesel generator set, the repair status and the main parts that have been replaced, and what problems there are in use, etc., so as to have a more comprehensive understanding of the machine. The second look: first check whether the model is obsolete, then look at the condition of the diesel generator set from the outside, and check whether the parts are complete and whether there is any damage. Third test: Test the machine. The specific steps are: 1. Shake the flywheel up and down. If there is no sound or obvious shaking, it means that the gap between the crankshaft main journal and the bearing bush is not large; turn the flywheel. If there is no clicking sound, it means that the crankshaft connecting rod shaft The wear between the neck and the connecting rod shoe is not serious. 2
  • Nov
    29
    Preparation work before test run of diesel generator set
    Diesel generator set must be inspected before test run ◎ The steps for inspection before diesel engine test run are as follows: 1) Check whether the surface of the diesel generator set is clean; whether the anchor nuts, flywheel screws and other moving parts nuts are loose, and find out problems Tighten in time 2) Check whether the clearance of each part is correct. In particular, carefully check whether the clearance of each inlet and exhaust valve and the clearance of the pressure reducing mechanism meet the requirements. 3) Place each cylinder in the decompression position, rotate the crankshaft to check whether there are any abnormal sounds in the operation of each cylinder's parts, and whether the crankshaft rotates freely. At the same time, pump oil into a friction surface, then close the decompression mechanism and shake the crankshaft. Check whether the cylinder is leaking. If it feels laborious when shaking the crankshaft, it means the compression is normal. 4) Check the condition of the fuel supply system. The steps are as follows: Check whether the ventilation hole on the fuel tank cap is smooth. If there is dirt in the hole, clean it out. Check whether the diesel fuel added meets the required grade, whether the oil quantity is sufficient, and whether it is