    Working principle and maintenance of synchronous generator (electric ball)
    Generator sets generally use synchronous generators (also commonly known as electric balls) to convert the rotating mechanical energy of the diesel engine into electrical energy. Various electrical equipment must rely on the power generated by it to work, so the working performance requirements of the synchronous generator are very high. . The working principle of synchronous generatorcopyright by:www.hxdlkj.com Synchronous generator is manufactured based on the principle of electromagnetic induction. Modern alternators are usually composed of two parts of coils; in order to increase the strength of the magnetic field, part of the coil is wound in a groove on the inner wall of a cylinder made of metal sheets with good magnetic conductivity. This cylinder is fixed on the base and is called stator. The coil in the stator can output induced electromotive force and induced current, so it is also called an armature. The other part of the coil of the generator is wound in the groove of a cylinder made of metal sheets with strong magnetic permeability in the stator cylinder, which is called the rotor. An axis passes through
  • Apr
    15
    Common causes of diesel generator set failures
    Every day, many users and friends come to consult about diesel generator set failures. In order to let everyone know the causes and treatment methods of common failures simply and clearly, the staff of Haixing Power have sorted it out and shared it with everyone. We hope it will be useful to everyone. . Introduction to common faults: 1. When the generator load is too low, why does the exhaust pipe sometimes drip oil? Since there are many places in the engine that use pressure seals, such as between the cylinder liner - piston - piston ring, and between the supercharger and the supercharger rotor shaft, this kind of seal is generally fully exerted when the engine is under about 1/3 of the load. function, and slight leakage may occur when the load is small. Therefore, foreign engine manufacturers generally emphasize this in their manuals. If the unit is operated under a small load, as the running time continues, the following faults will occur: ①. The piston-cylinder liner seal is not good, and the oil will escape and enter the combustion chamber.
  • Apr
    08
    Haixing Power explains to you the causes and preventive measures of engine cylinder pull
    Engine cylinder pull refers to the occurrence of obvious longitudinal mechanical scratches and scratches on the inner wall of the cylinder within the movement range of the piston ring. In severe cases, melting wear occurs, causing the engine to have difficulty starting or stalling on its own. Cylinder pull is a major accident to the engine. According to the experience summary of Haixing Power technicians: the fundamental reason for the cylinder pull of the generator set is that it is difficult to form an oil film between the inner wall of the cylinder and the piston ring and piston, resulting in poor lubrication and even dry friction. There are many specific reasons for this situation, which can be summed up in three aspects: Piston group reasons 1. The piston ring gap is too small. If the opening clearance, side clearance or back clearance of the piston ring is too small, the piston ring will expand due to heat and become stuck when the engine is running, and it will be pressed tightly against the cylinder wall, or the piston ring will break and it will be easy to pull out grooves on the cylinder wall. 2. The piston pin comes out.
  • Mar
    22
    Haixing shares: operating points of diesel generator set
    Diesel generator set is an efficient power supply equipment composed of four parts: diesel engine, cooling water tank, generator, chassis, control box and fuel tank. Diesel generator sets are widely used in mining, railways, field construction sites, road traffic maintenance, electric power, factories, post offices, communities, buildings, schools, enterprises, hospitals and other departments because of their small size, flexibility, lightness, complete supporting facilities, and easy operation and maintenance. , as a backup power supply. As a long-established power generation equipment manufacturer, Haixing Power has accumulated rich experience in operating diesel generator sets, which we will share with you below. 1. Diesel engine running-in: New or overhauled diesel engines must be run-in for 60 hours before being put into full-load use. To improve the working condition of the moving parts of the diesel engine and improve the reliability and service life of the diesel engine. Running-in should consider the specific running-in plan depending on the purpose of the diesel engine and the towing method.
  • Mar
    22
    How to determine the capacity, number and speed of commonly used diesel generator sets during procurement
    Diesel generator sets that need to operate for a fixed period of time for a long time are called common diesel generator sets. There are three major difficulties in the purchase of this type of equipment, which is to determine the capacity, number and speed of the units. As a professional power generation equipment manufacturer, Haixing Power gives the following suggestions. 1. Determination of the capacity of commonly used diesel generator sets Copyright by: www.hxdlkj.com The output power of the unit in long-term continuous operation can meet the calculated load selection of the entire project, and the backup unit capacity of the generator set should be determined according to the importance of the load. The continuous output power of a diesel engine is generally 0.9 times the calibrated power. 2. Determination of the number of commonly used diesel generator sets. The number of commonly used diesel generator sets is usually set to more than 2 to ensure the continuity of power supply and adapt to changes in the power load curve. Only when the number of units is large can the power consumption be
  • Mar
    04
    Still worried about power? See Haixing Power explain the power of diesel generator set in detail
    When purchasing diesel generator sets, many users are obsessed with power. Some unscrupulous merchants on the market will take advantage of people's lack of understanding of power to set up purchasing traps, causing people to make wrong judgments when purchasing. Haixing Power, a professional manufacturer of diesel generator sets, will provide you with a detailed analysis of the knowledge related to the power of diesel generator sets. Engine power calibration is based on mechanical strength, thermal load strength, and fatigue life. The same generator set can be calibrated to different powers according to the load rate and the length of use. GB2820-2009 is equivalent to standard ISO8528 and is divided into four types of power according to usage requirements: 1. ESP, emergency backup power 2. LTP, limited time operating power 3. PRP, basic power 4. COP, continuous power emergency backup power (ESP) Emergency Standby power is fixed
  • May
    08
    How to protect the circuit of parallel diesel generator sets
    In fact, the so-called parallel operation of diesel generators means that two or more generators with the same rated voltage and the same phase are merged into the same bus to supply active power and reactive power to the system. This is the parallel operation of the generators. Then we start one generator set first, and then send the generated voltage to the bus. After the other generator set is started, it will be paralleled with the previous generator set at this time. At the moment of closing, The generator set will not experience abnormal inrush current, and the rotating shaft will not be subject to sudden impact. However, we should consider the overall current loop problem during parallel operation, so how should we protect the loop? Next, Haixing Power will give you a brief analysis. 1. The phenomenon of reverse power and reverse power is caused by the difference in rotation speed (frequency) and voltage of the generator sets. That is, one generator set has positive power, while the other generator set has negative power.
  • Apr
    29
    Reasons why the electromagnetic switch coil of diesel generator set is burned out
    As we all know, long-term use of diesel generator sets will cause some parts to wear out, and then they are not inspected and maintained during normal use. As the diesel generator sets accumulate over time, one day suddenly the diesel generator set cannot start and generate electricity. The electromagnetic switch coil of the machine is burned out. Next, Haixing Power will introduce to you the reasons why the electromagnetic switch coil burns out? The diesel generator set cannot start, and then the electromagnetic switch burns out, which often occurs in the holding coil. The reasons are as follows: 1. The holding coil of the diesel generator set is relatively thin, and current flows through the diesel generator set during the entire starting process, and the working time is long. ; The wire diameter of the suction coil is relatively thick and the working time is short. It only passes current for a moment before the end of the main circuit is turned on. 2. When the diesel generator set is in poor technical condition, the starting time is too long, causing the holding coil to overheat and burn out.
  • Apr
    22
    Analysis of relevant technologies for biogas power generation
    my country has used biogas to generate electricity for more than 30 years, but the domestic biogas power generation research and application market are still in an imperfect stage. Biogas power generation has received widespread attention and active promotion in some developed countries. The use of biomass energy to generate electricity and connect it to the grid accounts for about 10% of total energy in Western Europe.
  • Apr
    16
    Analysis of several common problems that cannot start the diesel generator set
    A diesel generator set is a generator set that uses diesel as the main fuel. Its working process is mainly to inject diesel into the combustion chamber accurately and timely, and the compressed air in the combustion chamber must reach a sufficient temperature for complete combustion. To meet the above two conditions, the diesel engine must have a high enough speed and a certain temperature in the cylinder when starting, so that the diesel generator set can work. When the diesel generator set cannot start, we must pay attention to observation in order to determine what is causing the diesel generator set to fail to start. Below, Haixing Power will introduce to you several common diesel generator sets that cannot start. problem. 1. When starting, you only hear the 'clucking' sound of the starter electromagnetic switch, or when starting for the first time, the starter drives the crankshaft to rotate slowly for a few times, and then there is a 'clucking' sound of the starter electromagnetic switch, but the crankshaft does not rotate. This phenomenon generally belongs to the 'broken grid' of the battery.