  • Apr
    08
    Haixing Power explains the reasons and preventive measures for engine cylinder pulling
    Engine cylinder pulling refers to obvious longitudinal mechanical scratches and scratches in the inner wall of the cylinder within the range of motion of the piston ring. In severe cases, melting wear occurs, causing the engine to start up or the engine to shut down on its own. Pulling the cylinder is a major accident in the engine. According to the experience summary of Haixing Power technicians, the fundamental reason for the cylinder pulling of the generator set is that it is difficult to form an oil film between the inner wall of the cylinder and the piston ring and the piston, which causes poor lubrication and even dry friction. There are many specific reasons for this situation. There are roughly three aspects to summarize: The reasons for the piston group 1. The gap between the piston ring is too small. If the opening gap, edge gap or back gap of the piston ring is too small, the piston ring is heat expansion and stuck when the engine is working, pressing tightly with the cylinder wall, or the piston ring is broken, it is easy to pull out the groove on the cylinder wall. 2. The piston pin burst out.
  • Mar
    22
    Haixing shares: Key points of operation of diesel generator sets
    The diesel generator set is an efficient power supply equipment composed of four major parts: diesel engine, cooling water tank, generator, chassis, control box, and fuel tank. Diesel generator sets are widely used in mines, railways, field construction sites, road traffic maintenance, power, factories, post offices, communities, buildings, schools, enterprises, hospitals and other departments as backup power sources. As an old power generation equipment manufacturer, Haixing Power has accumulated rich experience in diesel generator set operation, so I will share it with you below. 1. The diesel engine run-in new or overhauled diesel engine must be run-in for 60 hours before it is officially used before it can be put into full load. To improve the working condition of the diesel engine moving parts, improve the reliability and service life of the diesel generator set of the diesel engine. The run-in plan should be considered depending on the use of the diesel engine and the drag method.
  • Mar
    22
    How to determine the capacity, number of units and speed of commonly used diesel generator sets during procurement
    Diesel generator sets that need to operate for a long time during a fixed period are called commonly used diesel generator sets. There are three major difficulties in purchasing such equipment, namely, determining the capacity, number of units and speed of the unit. As a professional power generation equipment manufacturer, Haixing Power provides the following suggestions. 1. Determination of capacity of commonly used diesel generator sets copyright by: www.hxdlkj.com The output power according to the long-term continuous operation of the unit can meet the load selection of the entire project, and the capacity of the generator set backup unit should be determined based on the importance of the load. The continuous output power of the diesel engine is generally 0.9 times the calibration power. 2. Determine the number of commonly used diesel generator sets. The setting for determining the number of commonly used diesel generator sets is usually more than 2 units to ensure the continuity of power supply and adapt to changes in the applied electrical load curve. Only when the unit is large can it be used according to the power consumption
  • Mar
    04
    Still worrying about power? Watch Haixing Power explain the power of diesel generators in detail for you
    In the purchase of diesel generator sets, many users are confused about power. Some bad merchants on the market will also use their lack of understanding of power to set purchase traps, which leads to people making wrong judgments when purchasing. Haixing Power, a professional diesel generator set manufacturer, will analyze the relevant knowledge of diesel generator set power for you in detail. The basis for engine power calibration is mechanical strength, thermal load strength, and fatigue life. The same generator set can be calibrated to different powers according to the load rate and the length of use time. GB2820-2009 is equivalent to standard ISO8528, and is divided into four powers according to the usage requirements: 1. ESP, emergency backup power 2, LTP, limited-time operation power 3, PRP, basic power 4, COP, continuous power emergency backup power (ESP) Emergency backup power fixed
  • May
    08
    How to protect the circuit of the diesel generator set
    In fact, the so-called parallel operation of diesel generator sets means that two or more generators have equal rated voltages and the same phases, and are incorporated into the same busbar at the same time to supply active and reactive power to the system. This is the parallel operation of the generator. Then we are running a generator set first and then sending the generated voltage to the busbar. After the other generator set is started, it is parallel to the previous generator set. At the moment of closing, the generator set will not experience abnormal impact current, and the shaft will not be hit suddenly. However, when we carry out parallel processing, we should consider the overall current loop problem. So how should we protect the loop? Let’s briefly analyze it for you below. 1. The reverse work phenomenon is caused by different speed (frequency) and voltage of the generator set, that is, one generator set has positive work, while the other unit has negative work.
  • Apr
    29
    Causes of the electromagnetic switch coil burnout of diesel generator set
    As we all know, diesel generator sets will cause wear and tear in certain parts during long-term use, and then they will not be inspected and maintained during normal use. With such accumulation of time, the diesel generator set suddenly one day, and the generator electromagnetic switch coil burned out. Next, Haixing Power will introduce to you what are the reasons for the burnout of the electromagnetic switch coil? This causes the diesel generator set to fail to start, and then the electromagnetic switch is burned, which often occurs in the holding coil. The reasons are as follows: 1. The holding coil of the diesel generator set is relatively thin, and current passes through the entire starting process of the diesel generator set, which is long working time; the diameter of the pull-up coil is thicker and the working time is short, and the current passes through the moment before it is turned on at the end of the main circuit. 2. When the diesel generator set is in poor technical condition, the starting time is too long, which causes the retaining coil to overheat and burn.
  • Apr
    22
    Analysis of related technologies of biogas power generation
    my country has a history of using biogas to generate electricity for more than 30 years, but the domestic biogas power generation research and application market is still in an imperfect stage. Biogas power generation has received widespread attention and active promotion in some developed countries. The use of biomass energy to generate power grids accounts for about 10% of the total energy in Western Europe.
  • Apr
    16
    Analysis of several common problems of not starting diesel generator sets
    A diesel generator set is a generator set with diesel as the main fuel. Its working process is mainly to spray diesel into the combustion chamber accurately and promptly, and the compressed air in the combustion chamber must reach a sufficient temperature to be fully burned. To meet the above two conditions, it is necessary to have a sufficiently high speed and a certain temperature in the cylinder when the diesel engine is started, so that the diesel generator set can work. When the diesel generator set cannot be started, we must pay attention to the observation so that we can determine what causes the diesel generator set to fail to start. Next, Haixing Power will introduce several common problems of the diesel generator set cannot start. 1. When starting, only the starter electromagnetic switch is heard, or when the starter starts, the starter drives the crankshaft to rotate slowly a few times, and then the starter sounds like the starter electromagnetic switch, but the crankshaft does not rotate. This phenomenon generally belongs to the battery 'disconnection'
  • Apr
    09
    Haixing answers the reasons for damage to the piston ring of diesel generator set
    The piston ring is the core component inside the diesel generator set engine. It is used together with the cylinders, pistons, cylinder walls, etc. to seal the combustion chamber gas. Because the piston ring is affected by high temperature and high pressure and reciprocating movement during long-term use, the wear will be aggravated. Therefore, the piston ring is generally made of multi-alloy cast iron that is resistant to wear, high temperature and has high mechanical strength. Although the piston ring is made of multi-alloy materials, long-term use will still cause wear of the piston ring. When the piston ring wears to a certain extent, the elastic force of the piston ring begins to gradually decrease, and the gap at the top, the gap at the side and the back gap will gradually increase, which will have a weakening effect on the sealing performance of the combustion chamber. This will cause the diesel in the combustion chamber to be unable to be completely burned, thereby increasing carbon deposits in the piston ring. So, what are the reasons that aggravate the wear of the piston ring? How can we avoid it? The sea is moving below
  • Apr
    03
    Do a good job of heat dissipating the generator set correctly
    With the continuous recovery of the weather in 2015, some cities have entered high temperatures. Haixing Generator Group pointed out that while the temperature continues to rise, more companies are purchasing generator set water pumps. Everyone was worried that the generator set was not dissipating well, so they bought relevant equipment in advance in order to have a safe summer. Haixing Generator said that the generator set relies on a cooling pump to dissipate heat. In addition to the quality of the coolant, it must be paid attention to, and the sealing is also worth testing. Many generator sets do not do well in heat dissipation because the machine itself is poorly sealed and the liquid cannot cool down and is put into use again. In this case, you cannot just replace the cooling pump, but re-check and thoroughly seal it. In addition, generator sets must be heat dissipated for high temperatures, especially those equipment that operate for a long time. Here we recommend Haixing Cummins diesel diesel generator set for everyone, with good sealing and stable operation