18553382068 13951158508
News Center
front page / News Center
  • Jan
    15
    Performance and advantages of Cummins generator set
    The Cummins generator set uses Dongfeng Cummins B and C series engines, with advanced technology and reliable performance. It is equipped with Wuxi New Era Stanford generators that withstand the voltage and frequency recovery during instant loading. In addition, the original design of built-in multi-stage vibration damping system can effectively eliminate vibration during unit operation, so that the control system and electrical components are protected; it can also provide very reliable power in extremely harsh environments. Advantages of Cummins generator sets: 1. After several Cummins generator sets are merged, a high-power generator set will supply power to the load. The number of machines can be determined according to the size of the load (the generator set consumes the lowest fuel under the operating conditions of 75% of the rated load), so as to save diesel and reduce the generator composition cost. Especially at present, diesel is relatively tight and oil prices are rising rapidly, saving diesel has become very important. 2. Achieve uninterruptible power supply to ensure normal production of the factory and unit conversion
  • Dec
    28
    Common knowledge on battery use and maintenance of diesel generator sets
    As we all know, the good performance of the overall performance of diesel generator sets cannot be separated from the effective coordination of various components. Therefore, the daily safe use and maintenance of equipment parts is very important. Today, Haixing Generator Set will introduce to you the common knowledge of battery use and maintenance of diesel generator sets to ensure the normal operation of the equipment. Daily use of battery of diesel generator set: 1. When the battery of the diesel generator set is not in use for a long time, appropriate charging must be given before use to ensure the normal capacity of the battery. Because normal operation and charging will cause some water in the battery to evaporate, this requires us to often add appropriate amounts of distilled water or pure water to the battery, but do not add it too much (using the scale of the battery plate as the standard). Otherwise, when the battery is discharged or charged, the electrolyte inside the diesel engine will surge out from the overflow hole in the filling port, causing corrosion and damage to surrounding objects and the environment.
  • Nov
    02
    Haixing analyzes the reasons for abnormal valve noise of diesel generator set
    After the diesel generator set is running for a period of time, sometimes there will be abnormal valve noise. At this time, everyone does not need to panic, but should immediately stop the machine to check, find out the root cause of the abnormal valve noise, and solve it in time to ensure the normal production of the enterprise. Below, Haixing will make a simple analysis on the reasons for abnormal valve noise of diesel generator sets for reference. 1. The valve leakage sounds. The valve leakage sounds outside the valve room, which is more obvious at high load and low speed, and the sound increases with the increase of load. The main reason is that when reaming the valve seat, due to improper operation or excessive wear of the valve conduit, the valve seat is skewed or the valve gap is small, resulting in valve ablation, causing the valve to be closed tightly and leak. Treatment method: Remove the cylinder head, grind the valve, check the valve spring force, and readjust the valve clearance. 2. When the valve knock is running at idle speed, the valve rod is triggered between the tail end and its driving part.
  • Oct
    19
    Causes and solutions for the injector stuck in diesel generator set
    After the diesel generator set is used for a period of time, the fuel injection nozzle may become stuck due to improper operation or maintenance. So, what are the reasons that cause the fuel injector of the diesel generator set to get stuck, and how will it be solved after encountering the problem? Haixing will give you a brief introduction here. 1. The reason for the injector nozzle of the diesel generator set is stuck 1. The diesel is not clean, there are impurities in the high-pressure oil pipe, which causes the needle valve pair to be worn, causing the needle valve pair to be closed tightly, the high-pressure gas in the combustion chamber to rush backwards, and the needle valve pair pair is burned. In addition, the dirt on the injector pressure regulating spring, tappet and other parts are moved to the upper part of the injector needle valve through the injector lift, or the cotton rope and lead wire in the oil circuit to prevent oil leakage enter the injector through the high-pressure oil pipe, which will cause the needle valve pair to be stuck. 2. The outlet valve is worn, causing oil dripping when the injector stops injection, causing the injection nozzle to burn and accumulate carbon, causing the malfunctions such as jamming.
  • Oct
    09
    Operating procedures for Cummins diesel generator sets
    After purchasing a Cummins diesel generator set, customers should pay attention to safe use and strictly abide by operating procedures to ensure the normal operation of the diesel generator set. So, what are the specific operating procedures for Cummins diesel generator sets? Haixing will introduce it to you here. Preparation before starting the machine 1. Check whether the oil level of the diesel engine crankcase is normal and check whether the cooling water tank is cooled (cooling water and engine oil should be enough). 2. Open the diesel valve to clear the fuel pipeline. 3. Manually check whether there are any signs of jammed moving parts. 4. Whether the starting motor current meets the starting requirements. 5. Check whether the water pump, oil pump, and fan conveyor belt are normal. 6. After confirming the above check, start the diesel generator. 2 Start 1. Close the starting power switch and start. 2. Start with diesel generator
  • Sep
    11
    Fuel consumption calculation of diesel generator set
    If you want to understand the approximate operating costs before purchasing a diesel generator set, it is necessary to calculate the fuel consumption. Many people do not know much about the fuel consumption and calculation of the generator set. The following Haixing Power will give you a detailed answer. Generally speaking, the fuel consumption of diesel generators is related to the following two factors: 1. Fuel consumption rate. Different brands of diesel generators have different fuel consumption rates and different fuel consumption; 2. The size of the electricity load, if the load is larger, the throttle is larger, the fuel consumption will be larger, and the load is smaller, the relative fuel consumption will be smaller. To facilitate everyone to understand the approximate fuel consumption of the generator set, calculate the usage cost of the generator set; this gives some approximate reference values ​​(30kw-500kw). Fuel consumption of 30kw diesel generator set = 6.3 kg (kg) = 7.8 liters (L) 45kw diesel generator set = 9
  • Sep
    05
    Normal and emergency shutdown of diesel generator sets
    How to perform shutdown operation after the generator set is run? Just turn off the power supply directly? Hereinafter, Haixing will explain in detail the three operations of diesel generator set operation, normal shutdown, and emergency shutdown, so that everyone can learn from it. After the operating unit enters full speed, the generator voltage and frequency are normal and stable, the operator can open and close the generator. During the unit operation, the operator should also frequently observe whether the unit is operating normally, whether the control screen instrument indicator is in a political position, whether the control screen has pre-alarm indications, fuel tank fuel level and other operating parameters, and record the unit operating parameters regularly. Before the normal shutdown unit is shut down, the load is first separated, and then the unit is run without load for a certain period of time, so that the unit is fully cooled and then shut down. For some units with a shutdown valve installed, if you want to turn off the control screen key switch, use the unit to stop the operation
  • Aug
    29
    Analysis on oil dripping phenomenon of diesel generator set
    Many friends have found that there may be slight leakage inside the engine of a diesel generator set, which is the so-called oil dripping. What exactly causes the oil dripping? What are the detailed fault locations? Haixing will give detailed answers to friends in the following article. If the generator set is running under a small load, as the running time continues, the following faults will occur: 1. The piston-cylinder liner is not sealed well, the oil is rushing up, entering the combustion chamber to burn, and the exhaust gas emits blue smoke. 2. For supercharged diesel engines, due to low load and no load, the supercharged pressure is low. It is easy to cause the sealing effect of the supercharger oil seal (non-contact type) to decrease, and the engine oil penetrates into the supercharge chamber and enters the cylinder with the intake. 3. Some of the engine oil that rushes up to the cylinder participates in combustion, and some of the engine oil cannot be burned. Carbon deposits form at the valve, air intake, piston top, piston ring, etc., and some are discharged with the exhaust gas. In this way, the cylinder liner exhaust passage will gradually
  • Aug
    01
    Key points to note when using diesel generators
    Pay special attention to the safety of diesel generators when in use. Because it is different from other types of generator sets, Jiangsu Haixing should emphasize the points of attention when using diesel generators safely. For new or long-term generators that are not used for normal operation, they must undergo strict inspections, mainly check the winding insulation, wiring conditions, etc. If there is any inconsistency, they will be handled. After the diesel engine is started, the speed is slowly increased. After inspection and confirming that everything is intact, it can run no-load from low speed to rated speed. When running at no load, focus on checking the oil pressure, whether there are abnormal noises, excitation current, three-phase voltage changes, etc. If there are abnormal conditions, the machine should be stopped immediately for inspection. After finding out the situation, start again. If everything is normal, it can be put into normal operation. The operator must closely monitor the changes in the instrument on the control screen, whether it is within the permitted scope, and make corresponding adjustments. During operation, the operator shall maintain the live equipment
  • Jul
    16
    The launch of new mobile generator sets is another advancement in technology
    Summer is the peak period for power consumption in my country, and many regions have begun to implement measures to shut down and limit power. With the implementation of this measure, people's requirements for generator sets are getting higher and higher. The original bulky, fuel-consuming, noise-consuming and polluted generator sets are far from meeting the needs of society. According to news reports, on July 11, Cummins launched a new mobile generator set that meets the U.S. Environmental Protection Agency (EPA) off-highway Tier 4i emission level standards, and the units launched are rated at 150 kW and 200 kW, which can be used for rental and other mobile applications. These units are expected to be delivered on August 6, 2012. In addition to the above advantages, the new unit also has the following important functions: a housing that can reduce operating sound, which can achieve quiet operation; a standard cam locking distribution panel can achieve easy and fast cables.
  • Total 30 pages  Go to Page
  • Go
More than 20 years of experience in gas power generation engineering application. It has the ability to provide integrated operation services of technology, equipment, engineering design, construction, operation and services.

Contact us

18553382068
13951158508
2260661851@qq.com
2260661851
www.hxdlkj.com
all rights reserved Su ICP No. 19030651-1 Sitemap