18553382068 13951158508
News Center
front page / News Center / Technical support / If the diesel generator set is not used for a long time, it will be 'bad'?

If the diesel generator set is not used for a long time, it will be 'bad'?

Views: 0     Author: Site Editor     Publish Time: 2017-09-15      Origin: Site

Inquire

wechat sharing button
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

Will the diesel generator set be broken if it is in a state of static for a long time? This statement has puzzled many users. Haixing Power will tell you in detail why the diesel generator sets are 'stopped and damaged'.

The filter capacity of the filter is reduced.

The filter plays a role in filtration of diesel, engine oil or water to prevent impurities from entering the body. In diesel, oil and impurities are inevitable. Therefore, during the operation of the unit, the filter plays an important role. However, at the same time, these oil and impurities are deposited on the filter wall, causing the filter capacity to decrease. If too much is deposited, the oil circuit will not be smooth. In this way, the oil engine will be shocked due to the inability to supply oil (such as human beings lack of oxygen). Therefore, during the use of a normal generator set, it is recommended: 1. Replace three filters in common units every 500 hours; 2. Replace three filters in standby units every two years.

The water circulation of the cooling system water supply pipeline is not smooth.

The water pump, water tank and water supply pipeline have not been cleaned for a long time, which makes the water circulation poor, the cooling effect decreases, whether the water pipe joint is good, whether there is water leakage in the water tank and water channel, etc. If the cooling system is faulty, the consequences are: 1. The cooling effect is poor, which causes the water temperature in the unit to be too high and shut down; 2. The water tank leaks and the water level in the water tank will drop, and the unit will not be able to work normally (to prevent the water pipe from freezing when using the generator in winter, it is recommended to install a water heater in the cooling system).

Therefore, before the generator set that has been idle for a period of time is put into use again, a complete performance check must be conducted to confirm the status of the equipment.