Views: 0 Author: Site Editor Publish Time: 2013-06-19 Origin: Site
With the wide application of diesel generators in real life, accompanying safety accidents often occur. Diesel generatorsGenerator setGetting burned is no longer uncommon. In order to ensure that the overall normal operation of the production enterprise is not affected, Haixing has summarized the following methods to prevent diesel generators from being burned.
1. Keep the diesel generator set clean and hygienic
During the operation of the diesel generator set, if dust, water stains and other debris enter the interior, a short-circuit medium will be formed, which will damage the insulation layer of the wires, cause an inter-turn short circuit, increase the temperature and burn the diesel generator set. Therefore, dust, water stains and other debris should be prevented from entering the interior of the diesel generator set. At the same time, the exterior of the diesel generator set should be cleaned frequently to ensure that the heat dissipation of the diesel generator set is in good condition.
2. Regularly inspect the diesel engine
When the diesel generator set is in operation, especially the high-power diesel generator set, it is necessary to regularly check whether the anchor bolts, diesel generator set end covers, bearing glands, etc. are loose, and whether the grounding device is reliable. If it is found that the vibration of the diesel generator set increases, the noise increases, and odor occurs, the engine must be shut down as soon as possible to find out the cause and eliminate the fault.
3. Keep the operating current of the diesel generator set not too large
The diesel generator set will cause overload operation due to excessive load, low voltage or driven mechanical jamming. Therefore, when the diesel generator set is in operation, attention should be paid to regularly checking whether the transmission device is running flexibly and reliably, whether the concentricity of the coupling is standard, the flexibility of the gear transmission, etc. If any jamming is found, the machine should be stopped immediately to eliminate the fault and then start again. run.
4. Frequently check whether the three-phase current of the diesel generator set is balanced
The difference between any one phase current of the three-phase current of the diesel generator set and the average value of the other two phase currents is not allowed to exceed 10%, so as to ensure the safe operation of the diesel generator set. If it exceeds the limit, it indicates that the diesel generator set is faulty, and the cause should be identified and eliminated before operation.
The above are four methods to prevent the diesel generator set from being burned. Haixing reminds everyone to pay attention to daily cleaning and detailed inspections when using the diesel generator set, and strictly follow the safety operating procedures to ensure the safe operation of the diesel generator set.