As we all know, the good performance of the overall performance of diesel generator sets cannot be separated from the coordination of various components. Therefore, the daily safe use and maintenance of equipment parts is very important. Today, Haixing Generator Set will introduce to you the common knowledge of battery use and maintenance of diesel generator sets to ensure the normal operation of the equipment.
Daily use of diesel generator set batteries:
1. When the battery of the diesel generator set is not in use for a long time, appropriate charging must be given before use to ensure the normal capacity of the battery. Because normal operation and charging will cause some water in the battery to evaporate, this requires us to often add appropriate amounts of distilled water or pure water to the battery, but do not add it too much (using the scale of the battery plate as the standard). Otherwise, when the battery is discharged or charged, the electrolyte inside the diesel engine will surge out from the overflow hole in the filling port, causing corrosion and damage to surrounding objects and the environment.
2. Before adding liquid, first clean the dirt around the filling port to prevent it from falling into the battery compartment. Then open the filling port and then add liquid. To prevent the battery from starting the unit at low temperature, the battery capacity will not be output normally under low temperature environments, and long-term discharge may cause the battery to crack or explode.
3. Equipped with a floating charger to regularly maintain and charge the generator set battery.
Common knowledge on maintenance of diesel generator sets:
1. Use a wet cloth to frequently scrub the outside of the battery so that the pile head of the battery will not accumulate white acid-etching powder and extend the service life.
2. Open the water cap of the battery to see if the water level is in the normal position. The standard position is to be added to the middle of the upper and lower marking lines. When it is found that the water level is lower than the lower marking lines, distilled water must be added. If you can't get the distilled water at once, you can filter tap water to respond to the emergency.
3. Check whether the battery is charging normally. It can be measured by a three-meter. After starting the engine, measure the voltage at the poles of the battery. It must exceed 13V to be considered normal. If you find that the charging voltage is too low, you need to ask a professional to inspect the charging system. If there is no three-purpose meter, you can use your eyes to measure it: after the engine is started, open the battery and add water cap to see if there are any bubbles in each small grid. The normal situation is that bubbles keep coming out of the water, and the more you get, the more you will get; when you find that there is no bubble, it is likely that there is something wrong with the charging system. It is important to note that hydrogen will be produced during this inspection, so you must not conduct Mars during inspection to avoid the risk of explosion and fire.
The above is common knowledge about the use and maintenance of diesel generator sets. In order to extend the service life of the equipment, everyone should pay more attention to daily operations. As a professional generator set manufacturer, Haixing is mainly engaged in the production and sales of Dongfeng Cummins generator sets, Chongqing Cummins generator sets, Shangchai generator sets, Volvo generator sets and other products. The company's products have excellent quality and stable performance. Since its application in various industrial production industries, it has received unanimous praise from customers. Everyone is welcome to come and consult and purchase!