1. Product Overview
Yuchai Generator set is a Jiangsu Haixing Power Engineering Company that has won the titles of 'National User Satisfaction Enterprise' and 'National User Satisfaction Product' many times; it has been rated as 'China's Top Ten Integrity Enterprises' and 'Standardized Good Behavior Enterprises'. We will meet customers with fast and decisive service.
2. Product Features
Yuchai has produced diesel generator sets for more than 40 years, and its products are widely used in military, civilian, marine and other fields;
All supporting powers for Yuchai generator set products are made of diesel engines produced by Yuchai;
The supporting motors are all products from domestic and foreign manufacturers, mainly including: Wuxi New Era Stanford Motor, Tsinghua Taihao Three-Wave Motor, Italy imported Macati, Marali, Xungao Motor, etc.;
Digital control system, intelligent; it can provide products with different functions such as remote computer remote control, group control, telemetry, automatic convergence, and automatic fault protection according to different needs of users;
It has strong power, and can output the rated power of the nameplate below 2000m altitude, and can output 110% overload power within less than 1 hour;
The fuel consumption rate and lubricant consumption rate are much better than similar domestic products;
Low vibration, low noise, high reliability;
Low emissions and meet national requirements;
The product quality fully meets or exceeds relevant national standards;
Three guarantee periods of 14 months or 1500 hours;
The 1,168 service stations established by Yuchai Generator Group across the country will provide users with fast and timely excellent services.
3. Unit maintenance and cleaning
The maintenance of the generator set must be carried out under shutdown. In order to ensure that the generator set does not start accidentally, the negative cable of the generator set must be removed before cleaning.
The interior and exterior of the alternator should be cleaned regularly, and the cleaning frequency varies depending on the environment in the unit location. Before cleaning, disconnect all power sources and wipe off all dust, dirt, oil stains, water or any liquid on the surface. The ventilation net must also be cleaned. If these dust accidentally enters the coil, it will cause the coil to overheat or damage the insulation. Therefore, the dust and dirt will be sucked away with a vacuum cleaner. Do not use blowing or high-pressure water spray to clean it;
In order to avoid the generator set's moisture recovery and the insulation resistance is reduced, the generator must be dried.
4. Main parameters
Unit model | Unit power (KW) | Current (A) | Engine model | Engine power (KW) | Number of cylinders | ||
spare | Commonly used | spare | Commonly used | ||||
HX30GF | 33 | 30 | 54 | YC4D60-D21 | 44 | 40 | 4 |
HX50GF | 55 | 50 | 90 | YC4D85Z-D20 | 60.5 | 55 | 4 |
HX60GF | 70 | 60 | 108 | YC6B100-D20 | 73.5 | 70 | 6 |
HX80GF | 85 | 80 | 144 | YC6B135Z-D20 | 99 | 90 | 6 |
HX100GF | 110 | 100 | 180 | YC6B155L-D21 | 113 | 103 | 6 |
110 | 100 | 180 | YC6B170L-D20 | 125 | 114 | 6 | |
HX120GF | 132 | 120 | 216 | YC6A210L-D20 | 153 | 139 | 6 |
HX150GF | 165 | 150 | 270 | YC6G245L-D20 | 181 | 165 | 6 |
HX200GF | 220 | 200 | 360 | YC6M350L-D20 | 258 | 235 | 6 |
HX350GF | 385 | 350 | 630 | YC6T550L-D21 | 405 | 368 | 6 |
HX400GF | 440 | 400 | 720 | YC6T660L-D20 | 441 | 485 | 6 |
HX600GF | 660 | 600 | 1080 | YC6C1020L-D20 | 748 | 680 | 6 |
HX800GF | 880 | 800 | 1440 | YC6C1175L-D20 | 936 | 851 | 6 |
HX1000GF | 1000 | YC6L240ZD-D | 1000 | 1100 | 6 |
Unit model | Bore ╳ stroke (mm) | Exhaust volume (L) | Engine oil capacity L | Fuel consumption rate | Speed regulation method | Unit weight | Unit appearance net size | |
HX30GF | 108 | 115 | 4.214 | 11 | ≤230 | mechanical | 870 | 1800×750×1100 |
HX50GF | 108 | 115 | 4.214 | 13 | ≤199 | mechanical | 1320 | 2250×780×1380 |
HX60GF | 108 | 125 | 6.871 | 14-17 | ≤199 | mechanical | 1320 | 2250×780×1380 |
HX80GF | 108 | 125 | 6.871 | 14-17 | ≤197 | mechanical | 1550 | 2370×780×1380 |
HX100GF | 108 | 125 | 6.871 | 17 | ≤200 | mechanical | 1520 | 2580×980×1400 |
108 | 125 | 6.871 | 17 | ≤200 | mechanical | 1520 | 2580×980×1400 | |
HX120GF | 108 | 132 | 7.252 | 22 | ≤195 | mechanical | 1650 | 2600×1000×1400 |
HX150GF | 112 | 132 | 7.8 | 22-25 | ≤195 | mechanical | 1770 | 2700×1000×1300 |
HX200GF | 120 | 145 | 9.84 | 28 | ≤197 | mechanical | 2450 | 3010×1040×1820 |
HX350GF | 145 | 165 | 16.35 | 52 | ≤195 | mechanical | 3000 | 3300×1250×1850 |
HX400GF | 145 | 165 | 16.35 | 64 | ≤194 | electronic | 3300 | 3550×1260×1750 |
HX600GF | 200 | 210 | 39.58 | 180 | ≤195 | electronic | 4800 | 4000×1500×2000 |
HX800GF | 200 | 210 | 39.58 | 180 | ≤195 | electronic | 4800 | 4200×1550×2100 |
1. Product Overview
Yuchai Generator set is a Jiangsu Haixing Power Engineering Company that has won the titles of 'National User Satisfaction Enterprise' and 'National User Satisfaction Product' many times; it has been rated as 'China's Top Ten Integrity Enterprises' and 'Standardized Good Behavior Enterprises'. We will meet customers with fast and decisive service.
2. Product Features
Yuchai has produced diesel generator sets for more than 40 years, and its products are widely used in military, civilian, marine and other fields;
All supporting powers for Yuchai generator set products are made of diesel engines produced by Yuchai;
The supporting motors are all products from domestic and foreign manufacturers, mainly including: Wuxi New Era Stanford Motor, Tsinghua Taihao Three-Wave Motor, Italy imported Macati, Marali, Xungao Motor, etc.;
Digital control system, intelligent; it can provide products with different functions such as remote computer remote control, group control, telemetry, automatic convergence, and automatic fault protection according to different needs of users;
It has strong power, and can output the rated power of the nameplate below 2000m altitude, and can output 110% overload power within less than 1 hour;
The fuel consumption rate and lubricant consumption rate are much better than similar domestic products;
Low vibration, low noise, high reliability;
Low emissions and meet national requirements;
The product quality fully meets or exceeds relevant national standards;
Three guarantee periods of 14 months or 1500 hours;
The 1,168 service stations established by Yuchai Generator Group across the country will provide users with fast and timely excellent services.
3. Unit maintenance and cleaning
The maintenance of the generator set must be carried out under shutdown. In order to ensure that the generator set does not start accidentally, the negative cable of the generator set must be removed before cleaning.
The interior and exterior of the alternator should be cleaned regularly, and the cleaning frequency varies depending on the environment in the unit location. Before cleaning, disconnect all power sources and wipe off all dust, dirt, oil stains, water or any liquid on the surface. The ventilation net must also be cleaned. If these dust accidentally enters the coil, it will cause the coil to overheat or damage the insulation. Therefore, the dust and dirt will be sucked away with a vacuum cleaner. Do not use blowing or high-pressure water spray to clean it;
In order to avoid the generator set's moisture recovery and the insulation resistance is reduced, the generator must be dried.
4. Main parameters
Unit model | Unit power (KW) | Current (A) | Engine model | Engine power (KW) | Number of cylinders | ||
spare | Commonly used | spare | Commonly used | ||||
HX30GF | 33 | 30 | 54 | YC4D60-D21 | 44 | 40 | 4 |
HX50GF | 55 | 50 | 90 | YC4D85Z-D20 | 60.5 | 55 | 4 |
HX60GF | 70 | 60 | 108 | YC6B100-D20 | 73.5 | 70 | 6 |
HX80GF | 85 | 80 | 144 | YC6B135Z-D20 | 99 | 90 | 6 |
HX100GF | 110 | 100 | 180 | YC6B155L-D21 | 113 | 103 | 6 |
110 | 100 | 180 | YC6B170L-D20 | 125 | 114 | 6 | |
HX120GF | 132 | 120 | 216 | YC6A210L-D20 | 153 | 139 | 6 |
HX150GF | 165 | 150 | 270 | YC6G245L-D20 | 181 | 165 | 6 |
HX200GF | 220 | 200 | 360 | YC6M350L-D20 | 258 | 235 | 6 |
HX350GF | 385 | 350 | 630 | YC6T550L-D21 | 405 | 368 | 6 |
HX400GF | 440 | 400 | 720 | YC6T660L-D20 | 441 | 485 | 6 |
HX600GF | 660 | 600 | 1080 | YC6C1020L-D20 | 748 | 680 | 6 |
HX800GF | 880 | 800 | 1440 | YC6C1175L-D20 | 936 | 851 | 6 |
HX1000GF | 1000 | YC6L240ZD-D | 1000 | 1100 | 6 |
Unit model | Bore ╳ stroke (mm) | Exhaust volume (L) | Engine oil capacity L | Fuel consumption rate | Speed regulation method | Unit weight | Unit appearance net size | |
HX30GF | 108 | 115 | 4.214 | 11 | ≤230 | mechanical | 870 | 1800×750×1100 |
HX50GF | 108 | 115 | 4.214 | 13 | ≤199 | mechanical | 1320 | 2250×780×1380 |
HX60GF | 108 | 125 | 6.871 | 14-17 | ≤199 | mechanical | 1320 | 2250×780×1380 |
HX80GF | 108 | 125 | 6.871 | 14-17 | ≤197 | mechanical | 1550 | 2370×780×1380 |
HX100GF | 108 | 125 | 6.871 | 17 | ≤200 | mechanical | 1520 | 2580×980×1400 |
108 | 125 | 6.871 | 17 | ≤200 | mechanical | 1520 | 2580×980×1400 | |
HX120GF | 108 | 132 | 7.252 | 22 | ≤195 | mechanical | 1650 | 2600×1000×1400 |
HX150GF | 112 | 132 | 7.8 | 22-25 | ≤195 | mechanical | 1770 | 2700×1000×1300 |
HX200GF | 120 | 145 | 9.84 | 28 | ≤197 | mechanical | 2450 | 3010×1040×1820 |
HX350GF | 145 | 165 | 16.35 | 52 | ≤195 | mechanical | 3000 | 3300×1250×1850 |
HX400GF | 145 | 165 | 16.35 | 64 | ≤194 | electronic | 3300 | 3550×1260×1750 |
HX600GF | 200 | 210 | 39.58 | 180 | ≤195 | electronic | 4800 | 4000×1500×2000 |
HX800GF | 200 | 210 | 39.58 | 180 | ≤195 | electronic | 4800 | 4200×1550×2100 |