1. Product Overview
Yuchai generator setIt is adopted by Jiangsu Haixing Power Engineering Company and has won the titles of 'National User Satisfaction Enterprise' and 'National User Satisfaction Product' for many times; it has been rated as 'China's Top Ten Integrity Enterprises' and 'Standardized Good Behavior Enterprise' , we will satisfy customers with fast and decisive service.
2. Product features
Yuchai has been producing diesel generator sets for more than 40 years, and its products are widely used in military, civilian, marine and other fields;
The supporting power of Yuchai's generator sets are all diesel engines produced by Yuchai itself;
The supporting motors are all products from domestic and foreign manufacturers, mainly including: Wuxi New Era Stanford Motor, Tsinghua Tellhow three-wave motor, Italian imported Makati, Marali, Xungao Motor, etc.;
The digital control system is intelligent; it can provide products with different functions such as remote computer remote control, group control, telemetry, automatic paralleling, and automatic fault protection according to the different needs of users;
It has strong power and can output nameplate rated power at an altitude of less than 2000m, and can output 110% overload power of rated power in less than 1 hour;
The fuel consumption rate and lubricating oil consumption rate are far superior to similar domestic products;
Low vibration, low noise and high reliability;
Low emissions, in line with national requirements;
Product quality fully meets or exceeds relevant national standards;
14 months or 1500 hours three-guarantee period;
The 1,168 service stations established by Yuchai Generator Group across the country will provide users with fast and timely excellent services.
3. Unit maintenance and cleaning
Generator setMaintenance must be carried out in the shutdown state. In order to ensure that the generator set will not start accidentally, the negative cable of the starting battery must be removed from the generator set before cleaning.
Both the inside and outside of the alternator should be cleaned regularly, and the frequency of cleaning will vary depending on the environment where the unit is located. Before cleaning, disconnect all power supplies, wipe off all dust, dirt, oil stains, water or any liquid on the surface, and clean the ventilation mesh. If the dust accidentally enters the coil, it will cause the coil to overheat or damage the insulation. , so use a vacuum cleaner to suck up dust and dirt, do not use air blowing or high-pressure water spray to clean;
In order to avoid the reduction of insulation resistance caused by the return of moisture in the generator set, the generator must be dried.
4. Main parameters
Unit model | Unit power (KW) | current (A) | Engine model | Engine power (kW) | Number of cylinders | ||
spare | Commonly used | spare | Commonly used | ||||
HX30GF | 33 | 30 | 54 | YC4D60-D21 | 44 | 40 | 4 |
HX50GF | 55 | 50 | 90 | YC4D85Z-D20 | 60.5 | 55 | 4 |
HX60GF | 70 | 60 | 108 | YC6B100-D20 | 73.5 | 70 | 6 |
HX80GF | 85 | 80 | 144 | YC6B135Z-D20 | 99 | 90 | 6 |
HX100GF | 110 | 100 | 180 | YC6B155L-D21 | 113 | 103 | 6 |
110 | 100 | 180 | YC6B170L-D20 | 125 | 114 | 6 | |
HX120GF | 132 | 120 | 216 | YC6A210L-D20 | 153 | 139 | 6 |
HX150GF | 165 | 150 | 270 | YC6G245L-D20 | 181 | 165 | 6 |
HX200GF | 220 | 200 | 360 | YC6M350L-D20 | 258 | 235 | 6 |
HX350GF | 385 | 350 | 630 | YC6T550L-D21 | 405 | 368 | 6 |
HX400GF | 440 | 400 | 720 | YC6T660L-D20 | 441 | 485 | 6 |
HX600GF | 660 | 600 | 1080 | YC6C1020L-D20 | 748 | 680 | 6 |
HX800GF | 880 | 800 | 1440 | YC6C1175L-D20 | 936 | 851 | 6 |
HX1000GF | 1000 | YC6L240ZD-D | 1000 | 1100 | 6 |
Unit model | Bore size/stroke (mm) | Exhaust volume (L) | Oil capacity L | fuel consumption rate | Speed regulation method | Unit weight | Unit appearance net dimensions | |
HX30GF | 108 | 115 | 4.214 | 11 | ≤230 | mechanical | 870 | 1800×750×1100 |
HX50GF | 108 | 115 | 4.214 | 13 | ≤199 | mechanical | 1320 | 2250×780×1380 |
HX60GF | 108 | 125 | 6.871 | 14-17 | ≤199 | mechanical | 1320 | 2250×780×1380 |
HX80GF | 108 | 125 | 6.871 | 14-17 | ≤197 | mechanical | 1550 | 2370×780×1380 |
HX100GF | 108 | 125 | 6.871 | 17 | ≤200 | mechanical | 1520 | 2580×980×1400 |
108 | 125 | 6.871 | 17 | ≤200 | mechanical | 1520 | 2580×980×1400 | |
HX120GF | 108 | 132 | 7.252 | 22 | ≤195 | mechanical | 1650 | 2600×1000×1400 |
HX150GF | 112 | 132 | 7.8 | 22-25 | ≤195 | mechanical | 1770 | 2700×1000×1300 |
HX200GF | 120 | 145 | 9.84 | 28 | ≤197 | mechanical | 2450 | 3010×1040×1820 |
HX350GF | 145 | 165 | 16.35 | 52 | ≤195 | mechanical | 3000 | 3300×1250×1850 |
HX400GF | 145 | 165 | 16.35 | 64 | ≤194 | electronic | 3300 | 3550×1260×1750 |
HX600GF | 200 | 210 | 39.58 | 180 | ≤195 | electronic | 4800 | 4000×1500×2000 |
HX800GF | 200 | 210 | 39.58 | 180 | ≤195 | electronic | 4800 | 4200×1550×2100 |
1. Product Overview
Yuchai generator setIt is adopted by Jiangsu Haixing Power Engineering Company and has won the titles of 'National User Satisfaction Enterprise' and 'National User Satisfaction Product' for many times; it has been rated as 'China's Top Ten Integrity Enterprises' and 'Standardized Good Behavior Enterprise' , we will satisfy customers with fast and decisive service.
2. Product features
Yuchai has been producing diesel generator sets for more than 40 years, and its products are widely used in military, civilian, marine and other fields;
The supporting power of Yuchai's generator sets are all diesel engines produced by Yuchai itself;
The supporting motors are all products from domestic and foreign manufacturers, mainly including: Wuxi New Era Stanford Motor, Tsinghua Tellhow three-wave motor, Italian imported Makati, Marali, Xungao Motor, etc.;
The digital control system is intelligent; it can provide products with different functions such as remote computer remote control, group control, telemetry, automatic paralleling, and automatic fault protection according to the different needs of users;
It has strong power and can output nameplate rated power at an altitude of less than 2000m, and can output 110% overload power of rated power in less than 1 hour;
The fuel consumption rate and lubricating oil consumption rate are far superior to similar domestic products;
Low vibration, low noise and high reliability;
Low emissions, in line with national requirements;
Product quality fully meets or exceeds relevant national standards;
14 months or 1500 hours three-guarantee period;
The 1,168 service stations established by Yuchai Generator Group across the country will provide users with fast and timely excellent services.
3. Unit maintenance and cleaning
Generator setMaintenance must be carried out in the shutdown state. In order to ensure that the generator set will not start accidentally, the negative cable of the starting battery must be removed from the generator set before cleaning.
Both the inside and outside of the alternator should be cleaned regularly, and the frequency of cleaning will vary depending on the environment where the unit is located. Before cleaning, disconnect all power supplies, wipe off all dust, dirt, oil stains, water or any liquid on the surface, and clean the ventilation mesh. If the dust accidentally enters the coil, it will cause the coil to overheat or damage the insulation. , so use a vacuum cleaner to suck up dust and dirt, do not use air blowing or high-pressure water spray to clean;
In order to avoid the reduction of insulation resistance caused by the return of moisture in the generator set, the generator must be dried.
4. Main parameters
Unit model | Unit power (KW) | current (A) | Engine model | Engine power (kW) | Number of cylinders | ||
spare | Commonly used | spare | Commonly used | ||||
HX30GF | 33 | 30 | 54 | YC4D60-D21 | 44 | 40 | 4 |
HX50GF | 55 | 50 | 90 | YC4D85Z-D20 | 60.5 | 55 | 4 |
HX60GF | 70 | 60 | 108 | YC6B100-D20 | 73.5 | 70 | 6 |
HX80GF | 85 | 80 | 144 | YC6B135Z-D20 | 99 | 90 | 6 |
HX100GF | 110 | 100 | 180 | YC6B155L-D21 | 113 | 103 | 6 |
110 | 100 | 180 | YC6B170L-D20 | 125 | 114 | 6 | |
HX120GF | 132 | 120 | 216 | YC6A210L-D20 | 153 | 139 | 6 |
HX150GF | 165 | 150 | 270 | YC6G245L-D20 | 181 | 165 | 6 |
HX200GF | 220 | 200 | 360 | YC6M350L-D20 | 258 | 235 | 6 |
HX350GF | 385 | 350 | 630 | YC6T550L-D21 | 405 | 368 | 6 |
HX400GF | 440 | 400 | 720 | YC6T660L-D20 | 441 | 485 | 6 |
HX600GF | 660 | 600 | 1080 | YC6C1020L-D20 | 748 | 680 | 6 |
HX800GF | 880 | 800 | 1440 | YC6C1175L-D20 | 936 | 851 | 6 |
HX1000GF | 1000 | YC6L240ZD-D | 1000 | 1100 | 6 |
Unit model | Bore size/stroke (mm) | Exhaust volume (L) | Oil capacity L | fuel consumption rate | Speed regulation method | Unit weight | Unit appearance net dimensions | |
HX30GF | 108 | 115 | 4.214 | 11 | ≤230 | mechanical | 870 | 1800×750×1100 |
HX50GF | 108 | 115 | 4.214 | 13 | ≤199 | mechanical | 1320 | 2250×780×1380 |
HX60GF | 108 | 125 | 6.871 | 14-17 | ≤199 | mechanical | 1320 | 2250×780×1380 |
HX80GF | 108 | 125 | 6.871 | 14-17 | ≤197 | mechanical | 1550 | 2370×780×1380 |
HX100GF | 108 | 125 | 6.871 | 17 | ≤200 | mechanical | 1520 | 2580×980×1400 |
108 | 125 | 6.871 | 17 | ≤200 | mechanical | 1520 | 2580×980×1400 | |
HX120GF | 108 | 132 | 7.252 | 22 | ≤195 | mechanical | 1650 | 2600×1000×1400 |
HX150GF | 112 | 132 | 7.8 | 22-25 | ≤195 | mechanical | 1770 | 2700×1000×1300 |
HX200GF | 120 | 145 | 9.84 | 28 | ≤197 | mechanical | 2450 | 3010×1040×1820 |
HX350GF | 145 | 165 | 16.35 | 52 | ≤195 | mechanical | 3000 | 3300×1250×1850 |
HX400GF | 145 | 165 | 16.35 | 64 | ≤194 | electronic | 3300 | 3550×1260×1750 |
HX600GF | 200 | 210 | 39.58 | 180 | ≤195 | electronic | 4800 | 4000×1500×2000 |
HX800GF | 200 | 210 | 39.58 | 180 | ≤195 | electronic | 4800 | 4200×1550×2100 |