1. Product Overview
Mercedes Benz generator setJiangsu Haixing Power Engineering Company selected original German Mercedes-Benz (MTU) series diesel engines to configure British-owned Guangzhou Inge, Sino-German joint venture Wuxi Siemens, Stamford, and Shanghai generators. Mercedes-Benz (MTU) series units are equipped with MDEC electronic control series, which have functions such as self-checking, fault alarm indication, and storage records. Its products are widely used in ships, heavy-duty vehicles, engineering machinery, railway locomotives, etc. As a supplier of land, marine and railway power systems and engines for power generation equipment, Mercedes-Benz generator sets are world-famous for their high-reliability products and quality services.
2. Product features
V-shaped arrangement with 90° angle, water-cooled four-stroke, exhaust gas turbocharging, intercooling
The 2000 series uses an electronically controlled unit pump for fuel injection, and the 4000 series uses a common rail fuel injection system.
Advanced electronic management system (MDEC), excellent ECU alarm function, self-diagnosis system can detect more than 300 engine fault codes
Optimized fuel control system (minimum 189g/kwh)
The 4000 series engine has an automatic cylinder reduction function under light load conditions.
The overhaul time for 2000 series and 4000 series engines is 24,000 hours and 30,000 hours respectively.
Mercedes-Benz generator set emissions are optimized to meet the German TA-Luft standard, the California Atmospheric Resources Board CARB standard, the Environmental Protection Agency EPA standard, and the European Community EURO non-highway vehicle emissions
3. How to deal with abnormal operation noises
The rotor rubs against the stator insulation paper or slot wedge;
Bearing wear or foreign matter such as sand in the oil;
The stator and rotor cores are loose;
The stator winding is misconnected or short-circuited.
4. Cleaning treatment
When performing maintenance on the Mercedes-Benz generator set, it must be carried out with the machine shut down, and the negative cable of the starting battery of the unit must be removed to ensure that the unit does not start accidentally.
Both the inside and outside of the alternator should be cleaned regularly, and the frequency of cleaning depends on the environment where the unit is located. Disconnect all power supplies before cleaning, wipe off all dust, dirt, oil stains, water or any liquid on the surface, and clean the ventilation mesh, because these things entering the coil will overheat the coil or damage the insulation. Use a vacuum cleaner to suck up dust and dirt as much as possible. Do not use air blowing or high-pressure water spray to clean.
The insulation resistance of the generator is reduced due to the return of moisture in the generator, so thedynamoProceed to dry.
5. Company Profile
Jiangsu Haixing Power Engineering Co., Ltd., located in Guxi Industrial Park, Taixing City, Jiangsu Province, is a professional manufacturer focusing on the design, installation, construction and technical services of environmental management projects, as well as the production, sales and maintenance of generator sets. The company mainly produces Dongfeng Fengshen generator sets, Dongfeng Cummins generator sets, Dongfeng Renault generator sets and Volvo generator sets, among which Mercedes-Benz generator sets are sold at home and abroad.
Since its establishment, Haixing Power Engineering has continuously focused on the technology research and development of generator sets, expanded the production scale of generator sets, improved generator set-related services, and gradually developed into a new and modern well-known private enterprise in Taizhou City. The company has a complete organization and management system, rich human resources, advanced technology research and development and process equipment capabilities, and complete testing equipment. The 'Haixing' brand 20-2000Kw diesel generator sets produced are widely used in shipping, petrochemical industry, highways, railways, water conservancy hubs, municipal engineering, postal and telecommunications, industrial and mining enterprises, hotels and other fields.
6. Technical parameters
Unit model | Unit power(KW) | Rated power | Diesel engine model | brand | Diesel engine power (KW) 1h/12h | Number of cylinders | |
spare | Rated | ||||||
HX500GF | 560 | 500 | 903 | 12V2000623 | MTU | 625/565 | 12 |
HX576GF | 630 | 576 | 1040 | 12V2000G63 | MTU | 680/625 | 12 |
HX670GF | 740 | 670 | 1209 | 16V2000G23 | MTU | 805/720 | 16 |
HX720GF | 800 | 720 | 1300 | 16V2000663 | MTU | 895/805 | 16 |
HX800GF | 880 | 800 | 1444 | 18V2000663 | MTU | 985/895 | 18 |
HX1060GF | 1110 | 1060 | 1913 | 12V4000621 | MTU | 1330/1205 | 12 |
HX1200GF | 1320 | 1200 | 2166 | 16V4000G21 | MTU | 1465/1330 | 12 |
HX1440GF | 1550 | 1440 | 2599 | 16V4000621 | MTU | 1760/1600 | 16 |
HX1630GF | 1800 | 1630 | 2942 | 16V4000661 | MTU | 1940/1760 | 16 |
HX2000GF | 2200 | 2000 | 3610 | 20V4000G22 | MTU | 2420/2200 | 20 |
HX2200GF | 2400 | 2200 | 3971 | 20V4000G62 | MTU | 2670/2420 | 20 |
1. Product Overview
Mercedes Benz generator setJiangsu Haixing Power Engineering Company selected original German Mercedes-Benz (MTU) series diesel engines to configure British-owned Guangzhou Inge, Sino-German joint venture Wuxi Siemens, Stamford, and Shanghai generators. Mercedes-Benz (MTU) series units are equipped with MDEC electronic control series, which have functions such as self-checking, fault alarm indication, and storage records. Its products are widely used in ships, heavy-duty vehicles, engineering machinery, railway locomotives, etc. As a supplier of land, marine and railway power systems and engines for power generation equipment, Mercedes-Benz generator sets are world-famous for their high-reliability products and quality services.
2. Product features
V-shaped arrangement with 90° angle, water-cooled four-stroke, exhaust gas turbocharging, intercooling
The 2000 series uses an electronically controlled unit pump for fuel injection, and the 4000 series uses a common rail fuel injection system.
Advanced electronic management system (MDEC), excellent ECU alarm function, self-diagnosis system can detect more than 300 engine fault codes
Optimized fuel control system (minimum 189g/kwh)
The 4000 series engine has an automatic cylinder reduction function under light load conditions.
The overhaul time for 2000 series and 4000 series engines is 24,000 hours and 30,000 hours respectively.
Mercedes-Benz generator set emissions are optimized to meet the German TA-Luft standard, the California Atmospheric Resources Board CARB standard, the Environmental Protection Agency EPA standard, and the European Community EURO non-highway vehicle emissions
3. How to deal with abnormal operation noises
The rotor rubs against the stator insulation paper or slot wedge;
Bearing wear or foreign matter such as sand in the oil;
The stator and rotor cores are loose;
The stator winding is misconnected or short-circuited.
4. Cleaning treatment
When performing maintenance on the Mercedes-Benz generator set, it must be carried out with the machine shut down, and the negative cable of the starting battery of the unit must be removed to ensure that the unit does not start accidentally.
Both the inside and outside of the alternator should be cleaned regularly, and the frequency of cleaning depends on the environment where the unit is located. Disconnect all power supplies before cleaning, wipe off all dust, dirt, oil stains, water or any liquid on the surface, and clean the ventilation mesh, because these things entering the coil will overheat the coil or damage the insulation. Use a vacuum cleaner to suck up dust and dirt as much as possible. Do not use air blowing or high-pressure water spray to clean.
The insulation resistance of the generator is reduced due to the return of moisture in the generator, so thedynamoProceed to dry.
5. Company Profile
Jiangsu Haixing Power Engineering Co., Ltd., located in Guxi Industrial Park, Taixing City, Jiangsu Province, is a professional manufacturer focusing on the design, installation, construction and technical services of environmental management projects, as well as the production, sales and maintenance of generator sets. The company mainly produces Dongfeng Fengshen generator sets, Dongfeng Cummins generator sets, Dongfeng Renault generator sets and Volvo generator sets, among which Mercedes-Benz generator sets are sold at home and abroad.
Since its establishment, Haixing Power Engineering has continuously focused on the technology research and development of generator sets, expanded the production scale of generator sets, improved generator set-related services, and gradually developed into a new and modern well-known private enterprise in Taizhou City. The company has a complete organization and management system, rich human resources, advanced technology research and development and process equipment capabilities, and complete testing equipment. The 'Haixing' brand 20-2000Kw diesel generator sets produced are widely used in shipping, petrochemical industry, highways, railways, water conservancy hubs, municipal engineering, postal and telecommunications, industrial and mining enterprises, hotels and other fields.
6. Technical parameters
Unit model | Unit power(KW) | Rated power | Diesel engine model | brand | Diesel engine power (KW) 1h/12h | Number of cylinders | |
spare | Rated | ||||||
HX500GF | 560 | 500 | 903 | 12V2000623 | MTU | 625/565 | 12 |
HX576GF | 630 | 576 | 1040 | 12V2000G63 | MTU | 680/625 | 12 |
HX670GF | 740 | 670 | 1209 | 16V2000G23 | MTU | 805/720 | 16 |
HX720GF | 800 | 720 | 1300 | 16V2000663 | MTU | 895/805 | 16 |
HX800GF | 880 | 800 | 1444 | 18V2000663 | MTU | 985/895 | 18 |
HX1060GF | 1110 | 1060 | 1913 | 12V4000621 | MTU | 1330/1205 | 12 |
HX1200GF | 1320 | 1200 | 2166 | 16V4000G21 | MTU | 1465/1330 | 12 |
HX1440GF | 1550 | 1440 | 2599 | 16V4000621 | MTU | 1760/1600 | 16 |
HX1630GF | 1800 | 1630 | 2942 | 16V4000661 | MTU | 1940/1760 | 16 |
HX2000GF | 2200 | 2000 | 3610 | 20V4000G22 | MTU | 2420/2200 | 20 |
HX2200GF | 2400 | 2200 | 3971 | 20V4000G62 | MTU | 2670/2420 | 20 |