front page / News Center / Company news / If the diesel generator set is not used for a long time, it is necessary to prevent 'stop damage'

If the diesel generator set is not used for a long time, it is necessary to prevent 'stop damage'

Views: 0     Author: Site Editor     Publish Time: 2024-04-15      Origin: Site

Inquire

wechat sharing button
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

Most of the diesel generator set failures are caused by the unit being in a static state for a long time. The various materials of the unit itself will undergo complex chemical and physical changes with the oil, cooling water, diesel, air, etc. This is mainly manifested in two aspects, which are summarized as follows : The filtration capacity of the filter decreases. The filter plays a role in filtering diesel, engine oil or water to prevent impurities from entering the body. Oil dirt and impurities are also inevitable in diesel, so during the operation of the unit, the filter plays a role. important role, but at the same time these oils or impurities are also deposited in On the filter wall, the filtration capacity of the filter will be reduced, and there will be too much sedimentation, and the oil circuit will not be smooth. In this way, when the oil engine is running under load, it will go into shock due to the inability to supply oil (like a person lacking oxygen). Therefore, during normal use of the generator set Among them, the editor of the diesel generator public platform recommends: 1. Every 500 for commonly used units Replace the third filter every hour; 2. Replace the third filter of the backup unit every two years. The water circulation in the cooling system water pipeline is not smooth. The water pump, water tank and water pipeline have not been cleaned for a long time, resulting in poor water circulation and reduced cooling effect. Whether the water pipe joints are in good condition, whether there are leaks in the water tank and water channels, etc. If the cooling system is faulty, it will cause The consequences are : 1. The cooling effect is not good and the water temperature in the unit is too high and the unit shuts down; 2. The water tank leaks and the water level in the water tank drops, and the unit will not work properly (in order to prevent the water pipes from freezing when using the generator in winter, it is recommended to water heater installed in the system). As a backup power source, many diesel generator sets cannot avoid being in a standby state most of the time. Therefore, in order to prevent the above phenomena in the unit, strengthening daily maintenance will be a good way.

More than 20 years of experience in gas power generation engineering application. It has the ability to provide integrated operation services of technology, equipment, engineering design, construction, operation and services.